[SFtrack] Commented: (XECS-1599) Correct use of poll() on sockets/pipes
[
http://track.sipfoundry.org/browse/XECS-1599?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel#action_30194
]
Dale R. Worley commented on XECS-1599:
--------------------------------------
This problem also applies to OsSocket::isReadyToRead() and similar methods.
> Correct use of poll() on sockets/pipes
> --------------------------------------
>
> Key: XECS-1599
> URL: http://track.sipfoundry.org/browse/XECS-1599
> Project: sipXecs
> Issue Type: Bug
> Components: sipXtackLib
> Reporter: Dale R. Worley
>
> SipClient does not use poll() correctly, as it assumes that the POLLIN datum
> will remain true until all available data has been read from a socket/pipe.
> But that is not the case -- see the thread starting with
> http://list.sipfoundry.org/archive/sipx-dev/thrd130.html#12913.
--
This message is automatically generated by JIRA.
-
If you think it was sent incorrectly contact one of the administrators:
http://track.sipfoundry.org/secure/Administrators.jspa
-
For more information on JIRA, see: http://www.atlassian.com/software/jira