Re: [sipX-dev] Default provider template kills sipXbridge
On Fri, 2009-06-26 at 12:38 -0400, Mark Gertsvolf wrote:
> sipXecs 4.0.1-015823
>
> Create a new gateway of type SIP trunk using "None" as a template. Fill
> in all available fields on the page and choose "route via internal
> bridge" option. Press OK.
> As a result of the above a new gateway of type "SIP trunk " is created
> with "registration" option turned on and no username/password specified.
Stop right there.
That's a sipXconfig bug - it should not have been willing to generate a
configuration with an internal inconsistency that bad.
> I am planning to report this behavior in a JIRA ticket. Do we have a
> consensus that this problem is worth reporting, or does anybody think I
> am being totally unreasonable complaining about this?
By all means report the fact that you were able to configure this broken
configuration.
The configtest for a component should not send an alarm; if anything,
sipxsupervisor should send it, but I think that the current service
status display is pretty good in this regard.